6 research outputs found

    Rapid and innovative instrumental approaches for quality and authenticity of olive oils

    Get PDF
    The quality of virgin olive oils is assessed through the determination of several analytical parameters, whose values must be within the ranges established by the different institutions involved. In addition to official methods, there is a strong need for simple, rapid, and environmentally friendly techniques for the quality control of virgin olive oils and for addressing the challenging task of determining geographical origin and detecting adulterants. Toward this purpose, some of the most interesting applications based on optical spectroscopic techniques, on the measurement of electrical characteristics and on the use of instruments equipped with electronic chemical sensors, including also other promising techniques are herein discussed. These techniques, adequately coupled with an appropriate statistical approach, appear to be promising for assessment of several quality-related parameters. The prediction of sensory attributes and of the oxidative status of virgin olive oils have also been reviewed by adopting these selected techniques, which are also considered to be potentially appropriate solutions for identification of the geographical origin of virgin olive oils and to assess their adulteration with cheaper oils. Overall, the techniques discussed are promising and cutting-edge approaches for the establishment of useful portable instruments for in situ monitoring of the quality of virgin olive oils. Practical applications: The simple, rapid, and environmentally friendly analytical approaches discussed herein represent promising analytical tools for assuring the authenticity and monitoring the quality of virgin olive oils. Such innovative techniques and tools need to be ring-tested and validated. Some innovative reviewed approaches will permit to develop useful portable instruments able to perform in situ appropriate controls also by small laboratories or olive oil mills with limited technical facilities. These equipments will be potentially usable also by trained \u201cnon-professional analytical skilled\u201d people. Some other approaches, rapid but more expensive, will be applicable mainly by quality control labs and will increase the number of samples analyzed per day, thus fostering laboratory proficiency and an effective fighting against olive oil fraud

    Microelettronica

    No full text
    Voce "Microelettronica" della Enciclopedia "Scienza e Tecnica" Indice della voce: Indice 1.La Microelettronica come fondamento della Societ\ue0 dell\u2019informazione 2.Chip e transistori 3.La storia della Microelettronica: gli inizi; i dispositivi MOS; la tecnologia planare del silicio; la nascita della Silicon Valley; l\u2019esplosione della Microelettronica 4.I Prodotti della Microelettronica: microprocessori e microcontrollori; memorie; componenti ASICs 5.Progettazione automatica 6.Lo stato dell\u2019arte 7.Le prospettiv

    Metalworking fluid degradation assessment by measurements of the electrical parameters at different temperatures

    No full text
    Metalworking fluids (MWFs) are currently used in the metal cutting industry for lubrication and to lower the temperature of both machine tools and worked pieces. Most MWFs are emulsions obtained by mixing an oil product with tap water in proper concentration (usually in the range 1% to 10%). In addition MWFs usually contain also other compounds, such as anti-microbial agents, emulsifiers and anti-corrosion products. MWFs degrade over time due to microorganism growth and contamination by processing by-products (such as tramp oil). Once worn-out the fluid must be properly disposed according to regulations using techniques such as chemical waste treatment, membrane filtration, evaporation or biological treatment. Since MWFs disposal and replacement represent a cost and have an impact on the environment, the product life-cycle must be extended as long as possible. Thus, assessment of the MWF degradation must be carried out at regular times. This work presents a technique, based on Electrical Impedance Spectroscopy, to assess MWF degradation and estimate the fluid pH value, a parameter playing an important role in the degradation process. The proposed method is based on the measurement of fluid impedance spectrum between 20 Hz and 2 MHz at four different temperatures (15, 25, 35 and 45 \uc2\ub0C). The data are analysed by means of Principal Component Analysis (PCA) and the results show the feasibility of fluids clustering according to the contamination level with good accuracy

    A portable sensor system for bacterial concentration monitoring in metalworking fluids

    No full text
    The detection of bacterial concentrations in metalworking fluids (MWFs), oil-in-water emulsions used in the cutting industries for cooling and lubrication, is important in order to extend the product life-cycle and plan its disposal according to regulations and legislations. The standard method of measuring culturable bacterial concentration is the plate count technique (PCT) that, however, has long response times and is not suitable for automatic implementation outside a laboratory. In this paper a portable sensor system that measures the bacterial concentration in liquid and semi-liquid media exploiting impedance microbiology is presented and tested for the application of MWF microbial monitoring. A set of MWF samples, taken from metalworking plants, have been tested and good agreement has been found between the system response and that of the PCT. The proposed system allows automated bacterial concentration measurements with shorter response times than the PCT (4 to 24 h vs. 24 to 72 h) and is suitable for in-the-field MWF monitoring

    A novel electrochemical method for olive oil acidity determination

    No full text
    Olive oil is a very important product due to its nutritional value, sensory and antioxidant properties. National and international regulations define basic quality parameters (such as acidity and peroxide index) to discriminate high quality oils (extra virgin olive oil) from those of lower quality. The procedures to measure acidity and peroxide index are manual titration techniques requiring a laboratory environment and trained personnel. In this paper a novel technique, based on electrical impedance spectroscopy, is presented to be suitable for the realization of a simple, low-cost, mobile instrument allowing such measurements to be carried out everywhere and by anybody, with substantial improvements of the current quality control of oil producers of any dimension. The presented method has been validated on 39 olive oil samples, featuring different levels of acidity, peroxide index and total phenolic content. The results show that the emulsion conductance is the electrical parameter best suited to discriminate the oil acidity. Moreover, since the emulsion conductance is also affected by the oil storage conditions (i.e. peroxide index), the presented technique can also be proposed, in a second time, to evaluate product agein

    An opto-electronic system for in-situ determination of peroxide value and total phenol content in olive oil

    No full text
    The quality of olive oil is essentially determined by the product free acidity and peroxide value, while the total phenol content is also important for a high antioxidant capacity. Generally, these parameters are measured with laboratory analysis, that are expensive and may require a few days. Thus, a cheap and easy technique usable by untrained personnel, "on-site" and producing results "in real time" during production is desirable, particularly as far as small olive oil mills and packaging centers are concerned. This paper describes a technique to determine peroxide value and total phenol content in olive oil, that is based on the measurement of optical density of an emulsion between a suitable chemical reagent and a small quantity of the oil of interest. The optical density is measured by illuminating the sample with a LED with peak wavelength of 569 nm for peroxide value and 835 nm for total phenol content. The experimental results show good correlation (R2 = 0.883 and 0.895 for peroxide value and total phenol content, respectively) between data measured with the standard methodology and the technique of this work, implemented also in the form of a portable embedded system
    corecore